KLD20S mini 2-way Motorized ball valve
Product Name:
KLD20S mini 2-way Motorized ball valve- Min order:1
Product Abstract:

- Product Description
Mini Electric ball valve also named mini motorized ball valve,motor operated valve,automatic&remote control valve,electrically actuated ball valve,water proof valve,Shut off valve.remote flow control valve,small or tiny motorized valve,low current electric ball valve,home electric brew valves,
It is considered "mini",because it only measures approx 3 inches wide by 3 inches tall ,and it only weights approx 0.3~0.5KG/pc.
Tofine-KLD20S is the upgrade version on the basis of Tofine-CWX15Q,
Tofine-KLD20S (With manual override),The price will be increased 1.6USD/pc if you need manual override.
Tofine-KLD20J( Without manual override),
IP67 water proof enclosure( IP67 protected against the effect of immersion up to 1M and totally against dust (NEMA 6 equivalent),
Food grade seal can be available for food applicaton.
Anti-UV case can be available for UV strong outdoors.
Size: 1/4"(DN8), 1/2"(DN15), 3/4"(DN20), 1"(DN25)
Material: Stainless steel, Nickle plated brass ,CPVC
Voltage: 5V,12V,24V,110~120V,220~240V
Wiring: B2,B3,BD3,KT2,B3S,BD3S,BP5 or others make-to-order.
Once opened or closed,the actuator does not continue to draw power due to an internal cutoff.
For B2,B3,BD3 wiring, If power loss occurs the valve will remain in its current positon,the actuaor is not spring return,
For KT2 wiring, If power loss occurs the valve will return to its original state,that is ,the valve will normally closed or normally open when power cut off,the actuator is "Actuator return" or "Spring return",the price of KT2 is always higher 4~6 USD than other wirings.http://www.flow-controls.com/news/What-is-fail-safe-or-normally-closed-open-motorized-ball-valve--16.html
Wokring pressure:1.0 Mpa

Size: Full port 1/4", 1/2",3/4", Reduced port 1",
For 1/2",3/4",1",you could select Stainless steel or Nickle plated brass,
For 1/4",so far you could only select nickle plated brass
,Please find below pictures to show the difference between full port 3/4" and reduced port 1",Full port 1" is also available,but please refer to other models.


Material:Brass or Stainless
Water proof enclosure,IP67 protected against the effect of immersion up to 1m,totally protected against dust (NEMA 6 equivalent)
Manual override is safe and convenient,it can easily operated by manul when power off.
Thread female connecction: NPT(for USA or Canada market) or BSP (for Australia or European market)
Where is the valve manual override and position indicator window of the motorized ball valves? It is on the actuator,see the below picture.
Manual override: Operation by manual when power cut off suddenly,Safe and convenient,
Window indicator or named position indicator:When the black line on the actuator is horizontal,the valve on,when vertical,valve off.

Features:
1.Mini Dimension suits for small equipment
2.Patented technology--floating seal structure
3.Long service life — 70,000- 100,000 circles
4.Low working current, suitable for battery driving
5.Manual override is safe and convenient
6.IP67 EnclosureApplications:
1.HVAC
2.Water treatment,Water leak detection &shut off system.
3.Chemical process
4.Small equipment for automatic control
5.Replacing solenoid valve, particularly when solenoid cannot work reliably




* Stainless steel with food seal Viton can also be sutiable for drinking water or other food standard application.
1.It is only permitted to use when power is cut.
2.Lift the hand-wheel, and turn it left or right until the valve is in place.
3.When the black line on the indicator is horizontal, the valve is on; when vertical, the valve is off.
4.Press down hand-wheel after using manual override in order to work properly when power is supplied.
1.The service life is the testing data in the condition of 1.0Mpa, 200L/h, tap water as working
medium. Different working occasions will influence the service life.
2.Manual shaft and hand-wheel will be replaced by rubber seal if manual override function is not needed.
3.Actuators are not direct-mount-on. Actuators are not recommended to be sold separately.
Wiring :B2,B3,BD3,KT2(Capacitor return), BD3S,B3S,BP5(With signal feedback), Kindly see below electric diagram,
You could also print attached file if you need.

If you need wiring with Signal Feeback,please select below Wirings B3S ,BD3S or BP5

B3S Wiring:
1,If SW is connected with GR,the valve will open and keep on,
At this time,LS.1 is closed,giving signal of opening totally.
2.If SW is connected with RD,the valve will close and keep off,
At this time,LS.2 is closed,giving signal of closing totally.* The feedback signal is asynchronous with valve location.
It is earlier than the location.
Feedback Loading capacity: 1) DC36V <=0.2A 2) AC220V <=50mA
BD3S Wiring:
1,If SW is closed,the valve will open and keep on,
At this time,LS.1 is closed,giving siganal of opening totally.
2,If SW is opened,the valve will close and keep off.
At this time,LS.2 is closed,giving signal of closing totally.* The feedback signal is asynchronous with valve location.
It is eariler than the location.
Feedback loading capacity:1) DC36V <=0.2A 2)AC220V <=50mA
BP5 Wiring(The actuator color will be changed into Red)
1) When Red line connected with power " +", black connected with power " -":,Valve turns counterclockwise to fully open,micro switch S1 close and send singal of closing fully,the client can disconnect the motor power.
2) When Red line connected with power "-",black connected with power "+":Valve turns clockwise to fully open,micro switch S2 close and send the signal of opening fully,the client can disconnect the motor power.
3) Above circuit of driving motor can adopt triode or bridge circuit consist of field-effect transistor,whatever driving circuit must have the motor equipped with braking function.B3S:Manual override is available for 5V or 12V,
BD3S: Manual override is available for 5V or 12V
BP5:Manual override is not available,but visual indicator can be avalilablePackage picture:8.5cm*7.0cm*11cm per piece, 23cm*13.5cm*33.5cm 10 pcs,Other sizescarton box suitable for different order quantity,
More details,please contact Amy by Email: sales@flow-controls.com,


KLD20S valve installation guide:1) Please use the valve in the inside of the voltage vange,the working voltage is the voltage
which will be input to the valve,the circuit will be destroyed if the voltage out of range,
and the valve will be hard to work if below the range.
2) The terminal is for testing,please cut it before using,
3) For the easy scaling place,we recommend installing the descaling equipment to guaranteelong life of the valves,
4) When fluid media including many scales and sands,we recommend installing filter equipment,or else,the leak may occur due to destroyed sealing.
5) Do not install the actuator upside down,
6) Please install protection facilities when installation outdoor.
7) Installation must be done as per technical rules,do not work disorderly.